Excel Insulated Angled Wall Radiation Shield
EXCEL chimney is specifically engineered for wood burning stoves, fireplaces and residential furnaces and it is suitable for use on appliances that burn:
- Wood - Oil - Coal - Gas - Charcoal -
Allowable Flue Gas Temperatures
Max Continuous 650°C (1200°F)
Brief Forced Firing 925°C (1700°F)
Tested To 1150°C (2100°F)
Clearance to Combustible Materials
2" clearance except in areas protected by factory-built supports certified for reduced clearance. EXCEL round and square supports permit the chimney to be installed with approximately 1 inch of clearance - in the area shielded by the support.
Construction
Flue: .016" stainless steel
Casing: .016" stainless steel
Seam: Interior and exterior seams are continuous seam welded
Insulation: Thermoplus continuous blanket
Wall thickness: 1"
Paint: All black EXCEL components are painted with Forrest “Stove Bright” flat black paint
The insulated angled wall radiation shield (thimble) is used when the chimney goes through a combustible exterior wall, with a 30 or 45 degree angle. A radiation shield (thimble) is installed on the exterior side of the wall to complete the installation. This part is used for fireplace installations only.
Note: 45° are approved for use in Canada only.
* Special Order. No returns on special order items