Replacement Kits
Honeywell Vented Millivolt Valve Conversions to SIT Valve
There were several repair kits released in 2006 for replacing Honeywell Millivolt Valves 10001782 (natural gas) and 10001759 (propane) on various Majestic and Vermont Castings Gas Units. These kits all include the appropriate fuel SIT Valve with all brackets, hardware and piezo igniter parts needed to do a complete replacement of the Honeywell Millivolt Valve. See the list below | |
Item Number | Description |
20010680 | RP 269 Honeywell to SIT Conversion Stardance & Radiance DV LP |
20010684 | RP 270 Honeywell to SIT Conversion Stardance & Radiance NV LP |
10008800 | RP 272 Honeywell to SIT Conversion LHE Series NG |
10008893 | RP 272 Honeywell to SIT Conversion LHE Series LP |
20010811 | RP 275 Honeywell to SIT Conversion Stardance & Radiance DV NG |
20010812 | RP 276 Honeywell to SIT Conversion Stardance & Radiance NV NG |
Stardance & Radiance Honeywell Vent-Free Millivolt Valve Conversions to SIT Valve
When existing inventory of the Honeywell Vent-Free Millivolt Valves is used up, direct field replacements of these valves will no longer be possible. MHSC has made available complete burner engines for field service on older units where the valve has failed. These kits include a rating plate and a new manual. These kits will work only on Stardance and Radiance Vent-Free units with drop-in burners. The part numbers for these items are listed below. | |
Item Number | Description |
30005086 | RUVSOD RADIANCE UV NG BURNER REPLACEMENT |
30005087 | RUVSOD RADIANCE UV LP BURNER REPLACEMENT |
30005088 | STARDANCE UV NG BURNER REPLACEMENT |
30005089 | STARDANCE UV LP BURNER REPLACEMENT |
Stardance & Radiance Honeywell Radio Frequency Valve Conversions to SIT RCSITEA Multi Function System
MHSC no longer has replacement Honeywell Radio Frequency Valves or Remote transmitters. Replacement kits have been designed for the units in the field that had the Radio Frequency Comfort Control System installed and now have valve failure. When installed, the units will be the same as the current Vermont Castings Radiance RADVTC and Stardance SDDVTC models. The kits include the NG control plate assembly (valve, pilot etc.), new rear shroud with junction box, new fan assembly, remote control, new rating label, instructions and current manual. For LP, a conversion kit needs to be ordered as well. See below for a list of all the kits. Item Number | |
Item Number | Part Description |
30005104 | Radiance RADVTC NG Burner Replacement Kit |
30005105 | Stardance SDDVTC NG Burner Replacement Kit |
20300165 | Radiance RADVTC NG to LP Conversion Kit |
20300126 | Stardance SDDVTC NG to LP Conversion Kit |
Discontinued CFM Fireplaces Using Honeywell Radio Frequency Valve Conversions to SIT RCSITEA Multi Function System
Replacement kits have been designed for discontinued CFM gas units in the field that had the Radio Frequency Comfort Control System installed and now have valve failure. MHSC has designed the kits for only the model listed below. The kits include a valve, valve bracket if needed, pilot assembly, pilot bracket if needed, remote control with receiver, piezo igniter with bracket and instructions. See below for a list of the kits. | |
Item Number | Part Description |
20301078 | DV360RFN / DV580RFN / DVRT36RFN / DVB4136RFN RF to RCSITEA Conversion |
20301079 | DV360RFP / DV580RFP / DVRT36RFP / DVB4136RFP RF to RCSITEA Conversion |
20301076 | 36XDVRFN RF to RCSITEA Conversion |
20301077 | 36XDVRFP RF to RCSITEA Conversion |
20301080 | RFSDV34RFN RF to RCSITEA Conversion |
20301081 | RFSDV34RFP RF to RCSITEA Conversion |
20301208 | LHEC20/30RFN / LHECDV20/30RFN / RHE32/42RFN / RHERHEDV32/42RFN RF to RCSITEA Conversion |
20301209 | LHEC20/30RFP / LHECDV20/30RFP / RHE32/42RFP / RHEDV32/42RFP RF to RCSITEA Conversion |
Official MHSC Bulletin 2010-04